Tampa Building Envelope Thermal Imaging Inspections

Weller Infrared Services provides professional thermal imaging inspections of building envelopes to help Tampa Bay commercial clients locate hidden moisture, damaged insulation, and air infiltration issues. Using high-quality FLIR thermal imaging cameras and FAA-licensed drones, we pinpoint problem areas that are invisible during conventional visual inspections.

We also perform ASTM E783-02(2018) — Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors — and ASTM E1105 — Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference.

Tampa Bay commercial high-rise buildings — building envelope thermal imaging inspection service area
Aerial drone view of commercial building roof and facade — Tampa Bay building envelope inspection by Weller Infrared Services
FLIR drone thermal image of commercial building showing heat loss through walls — Tampa Bay infrared building inspection
FLIR thermal scan showing air infiltration around window in Tampa commercial building — Weller Infrared Services
Standard photo of room showing moisture intrusion at window — Tampa Bay building envelope inspection
Infrared thermal image with arrow indicating moisture intrusion point in Tampa commercial building wall
Aerial drone photo of large commercial freezer facility — Tampa Bay building envelope and insulation inspection
Wind Maker ASTM E1105 window water penetration test equipment with Magnehelic pressure gauges — Tampa Bay building envelope testing by Weller Infrared Services
Blower door air leakage test setup in Tampa Bay building — ASTM E783 air infiltration testing by Weller Infrared Services

Why Tampa Building Envelope Thermal Imaging Requires Expertise

What sets Weller Infrared Services apart is real-world field experience, training by leading thermographers, and advanced education. Thermal imaging is not point-and-shoot technology. Building envelope inspections require proper technique and accurate interpretation. Without the right training, you risk paying for reports full of false positives or missed issues.

Our high-quality FLIR infrared surveys have helped countless Tampa Bay clients avoid costly repairs. Most envelope problems stem from lack of supervision during construction, poor workmanship, or improper materials — issues that can later lead to expensive remediation. Our ASTM E1105 water penetration testing and ASTM E783 air leakage testing can identify moisture intrusion and air leaks before exterior finishes are installed, potentially saving significant repair costs later.

Common Issues We Identify

  • Moisture and water intrusion in building walls and stucco systems
  • Missing, damaged, or improperly installed insulation
  • Air infiltration and thermal bridging around windows and doors
  • ASTM E1105 water penetration testing for windows, skylights, and curtain walls
  • ASTM E783 air leakage testing for installed exterior windows and doors
  • Pre-construction and post-construction envelope verification

Credentials

Level 3 Certified Infrared Thermographer #8339 Infraspection Institute
Building Science Thermographer #30937 FLIR Systems
Former Florida Certified Building Contractor
Former Florida Certified Roofing Contractor
ASTM/AAMA Window Testing
Building Performance Institute (BPI) Certified Blower Door and Duct Tester
FAA Licensed Drone Pilot
Journeyman Electrician Coursework
Infraspection Institute Level III Certified Infrared Thermographer seal — Mark Weller #8339, Tampa Bay thermal imaging inspector

Professional Infrared Service Throughout the Southern US

Call (888) 461-1115

Weller Infrared Services — Tampa Bay Level III Certified Infrared Thermographer

Professional thermal imaging inspections throughout Tampa Bay and the Southern US.

© 2026 Weller Infrared Services, Inc. All rights reserved.